Cardiovascular Disease· Topic 2.6 Valvular heart disease and cardiac murmurs· 2.6.9

Prosthetic valve thrombosis

Prosthetic valve thrombosis is thrombus on a prosthetic valve, most often a mechanical valve with inadequate anticoagulation, causing obstruction or embolism. It presents with heart failure, muffled prosthetic sounds, or embolic events, is confirmed by echocardiography and fluoroscopy, and is treated by surgery or fibrinolysis depending on severity.

5 min read7 practice questions7 key factsSubscriber article
  • Topic review
    The full article, organized the way the exam asks it.
  • ABIM-format MCQs
    Vignettes with an explanation for every wrong answer.
  • Key facts
    The numbers and thresholds worth memorizing, up front.
  • AI tutor
    MedBrain answers the question you're stuck on.

What this article covers

  • Overview

    Definition: prosthetic valve thrombosis is the formation of thrombus on a prosthetic heart valve, impairing leaflet or disc motion (obstruction) or causing embolism.

  • Epidemiology

    Predominantly affects mechanical valves, especially in the mitral position.

  • Risk factors

    Subtherapeutic or interrupted anticoagulation (the dominant risk).

  • Pathophysiology

    Thrombus on prosthetic material: stasis and inadequate anticoagulation allow thrombus to form on the sewing ring, discs, or leaflets.

  • Clinical features

    Exertional dyspnea and heart failure from obstruction.

  • Differential diagnosis

    Prosthetic valve endocarditis: infection with vegetations, positive blood cultures, and fever rather than bland thrombus (Prosthetic valve endocarditis).

  • Diagnosis

    Establish with echocardiography and fluoroscopy showing restricted leaflet or disc motion and thrombus, and distinguish from pannus and vegetation: the diagnostic basis is transthoracic and…

  • Management

    First-line, stratify by severity, side, thrombus size, and symptoms: obstructive left-sided thrombosis with heart failure is a surgical emergency in suitable patients.

  • Complications

    Acute valve obstruction, heart failure, and cardiogenic shock.

  • Prognosis

    Life-threatening when obstructive, with better outcomes after prompt treatment.

  • Prevention

    Maintain therapeutic anticoagulation at the valve-specific INR target (2.5 to 3.5 for most mechanical valves) with warfarin (not DOACs), monitored every 4 weeks.

Read the whole article

Subscribing to Internal Medicine opens every article, the full question bank and MedBrain, on the web, iPhone and Android.